
Testo 6743 dew point transmitter to -45 °Ctd with polymer humidity sensor, display, process connection G½ thread, analog output 4 to 20 mA and optional alarm plug with 2 switching outputs
Dew Point Transmitter (to -60 °Ctd) - testo 6743
Model No: testo 6743
Part No: 0555 6743
Testo 6743 dewpoint transmitter to -60 °Ctd, with display, process connection G1/2, analog output 4 to 20 mA, optional alarm plug with 2 switching outputs
- Dew point transmitter with a measuring range of -45 °Ctd to + 30 °Ctd, G½ thread and display
- Testo polymer humidity sensor with a high degree of accuracy and long-term stability
- Freely scalable analog output (4 to 20 mA) and optional alarm plug with 2 integrated switching outputs
Air, compressed air and gases are used in all areas of industry. Humidity and moisture are generally undesirable because they can cause damage or impair the quality of the end product. The use of measuring and control technology is recommended in order to monitor humidity in the network and prevent damage.
Our testo 6743 dew point transmitter was designed specifically for measuring trace humidity in compressed air or dry air. It boasts a polymer humidity sensor which features a high degree of accuracy and long-term stability.
Technical advantages offered by the testo 6743 dew point transmitter
- High accuracy: the testo 6743 dew point transmitter uses the Testo polymer sensor to measure humidity with a high degree of precision – up to ±1 K at 0 °Ctd (+32 °Ftd)
- Scalable analog output: the dew point transmitter converts the measured values into a standardized electrical signal, whereby the analog output can be scaled as required (4 to 20 mA)
- Alarm plug with 2 integrated switching outputs (optional): use the switching contact plug for MAX monitoring
- Practical format: the testo 6743 dew point transmitter features a compact and user-friendly design. For example, the housing can be rotated by 350°, enabling optimum alignment of the display
- Display with operating menu: convenient operation and on-site read-out of readings
Use the dew point transmitter to prevent damage (e.g. in refrigeration dryers or membrane dryers). This can save you a considerable amount of money, because if the quality of the end product is impaired in any way, it can prove costly. The cost of running adsorption dryers can also be reduced: accurate humidity-controlled chamber activation precisely adjusts the use of regenerated air to meet requirements – not at a preset time increment, which often creates unnecessary, excess consumption of regenerated air
Dewpoint/trace humidity | |
---|---|
Units | %RH, °C |
Calculated parameters | °Ctd, °Ftd, °CtA, °FtA, ppmv, mg/m3, °F |
Measuring range | -60 °Ctd to +30 °Ctd, -80 °CtdA to +15 °CtdA |
Measurement uncertainty | ± 2 °Ctd |
Response time | t90 〈= 60 sec for change from 13.2 °Ctd to -32.1 °Ctd t90 〈= 17sec for change from -32.2 °Ctd to 13 °Ctd |
Sensor | Polymer humidity sensor with protocolized trace humidity adjustment at -40 °Ctd (-40 °Ftd) |
Analog outputs | |
Current/accuracy | 4 to 20 mA (2-wire) / ±40 μA |
Measurement rate | 2 s |
Resolution | 12 bit |
load | 12 V DC: max. 100 W, 24 V DC: max. 650 W, 30 V DC: 950 W |
Scaling | Freely scalable via display buttons |
Voltage supply | 24 V DC (12 to 30 V DC permitted); with alarm plug (0554 3302) 20 to 28 V DC |
Current consumption | 21 mA (without alarm plug) 65 mA (with alarm plug) |
General technical data | |
Material/colour | Plastic, polyacrylamide |
Display | High intensity 7-segement display |
Rotatability (display positioning) | 350° around housing axis |
Thread / process connection | G½ thread or NPT½“ thread |
Protection class | IP65 (with plug attached and wire connected) |
Operating temperature (housing) | -20 to +70 °C (+4 to +158 °F) |
Storage temperature | -40 to +80 °C (-40 to +176 °F) |
Process pressure | max. 50 bar (725 psi) |
